Large
Array Full Systems
Large Array for Investiagational Assessment of Spinal
Damage
Tristan has a long history of design and development of large systems
for biomagnetic measurements. From components such as dewars for whole
head neuromagnetometers

100+ channel whole head dewar 37 position scalar/vector probe under
construction
to complete systems, Tristan can supply you with whatever biomagnetometer
system you need.
Tristan's capabilities include the following:
· Complex shape Dewars
· Liquid immersion or coil-in vacuum dewar construction
· Orthogonally oriented vector (BX,BY, BZ) detection coils
· Asymmetric gradiometers for improved sensitivity
Integral superconducting magnets
· Multi-axis dewar gantries
· Magnetically quiet motorized patient beds
· Vector and tensor reference arrays for noise cancellation
· Software for data analysis ranging from basic LabView
drivers to sophisticated magnetic dipole and current dipole fits
· Positioning
· --
Specific Examples of some of Tristan's large systems include the following:

5-axis Full motion dewar gantry 4-axis
bed
Model 663 Spinal Cord Measurement System
5-axis dewar gantry 4-axis bed
Tristan has built and delivered a fully integrated 61 channel magnetic
source imaging system for non-invasive measurements of spinal cord activity
and source localization. The system is adaptable for humans or animals.
Because spinal signals are action potentials, the system is designed
to acquire data at the rate of 108,000 samples per second on each of
its 80 channels (including reference channels), more than an order of
magnitude faster than conventional MEG devices. The system consists
of a sensor containing a large array of superconducting magnetic signal
detectors and reference channels for noise reduction; signal acquisition,
processing and display workstations; a sensor positioning gantry; a
patient bed; patient/sensor position indicator.
Model 684 Biomagnetometer (babySQUID®)
An 84 channel system for neuromagnetic measurements of neonates, it
features extremely close coil-to-room temperature spacing, inverted
coil orientation (the patient lies above the detector array), mm spatial
resolution and the ability to operate in an unshielded environment.
babySQUID® is described in http://www.tristantech.com/prod_baby.html.
Model 637 Biomagnetometer (GutSQUID®)
This system is designed to measure the Basic Electric Rhythm (BER) associated
with intestinal activity. The specific application is detection of Mesenteric
Ischemia, a life threatening condition with no conventional reliable
method of diagnosis. The 37 channel system features coil-in-vacuum construction,
axial and vector detection coils and the unique ability to vary the
position of the detection coils. This allows the researcher to adjust
the spatial frequency measurement capability of the system. Designed
to operate in a clinical setting, the model 637 operates in an unshielded
environment. Tristan's experience with coil-in-vacuum design is critical
for sensors that are both portable and adaptable to measurement at varying
orientations. Further information on gutSQUID® can be found at http://www.tristantech.com/prod_gut.html.
Model 5703 Ferritometer®
While not a high channel count system, the Ferritometer®-a clinical
system for assessment of liver iron stores-demonstrates our capability
to supply complex turn key systems for research or clinical applications.
Further information on the Ferritometer® can be found at http://www.tristantech.com/prod_biomagnet_liver_fe.html.

Many of Tristan's systems have been the result of a collaborative effort
between us and our customers. We can vary channel density (spatial frequency),
coil diameter (sensitivity and spatial resolution) and sensor spacing
(sensitivity and spatial resolution) to the requirements of the physiological
signals being measured. Please contact Tristan to discuss your particular
requirements.